Parquet input data format
Use the parquet input data format to parse
Apache Parquet files into Telegraf metrics.
Each row in the Parquet file becomes a metric, with columns mapped to
fields unless configured as tags, the measurement name, or the timestamp.
Configuration
[[inputs.file]]
files = ["metrics.parquet"]
data_format = "parquet"
## Columns to store as tags instead of fields.
# tag_columns = []
## Column to use as the measurement name.
# measurement_column = ""
## Column containing the metric timestamp.
## If not set, the time of parsing is used.
# timestamp_column = ""
## Format of the timestamp in timestamp_column.
# timestamp_format = ""
## Timezone for timestamps that don't include an offset.
# timestamp_timezone = ""tag_columns
Columns to store as tags instead of fields.
Type: array of strings
Default: []
measurement_column
The column to use as the measurement name. If not set, the input plugin’s default measurement name is used.
Type: string
Default: Not set
timestamp_column
The column containing the time for each metric. If not set, the time of parsing becomes the timestamp.
Type: string
Default: Not set
timestamp_format
The layout of values in timestamp_column.
Use unix, unix_ms, unix_us, unix_ns, or a
Go reference time layout such as
2006-01-02T15:04:05Z07:00.
For reference-time details, see
Parse timestamps.
Type: string
Default: Not set
timestamp_timezone
Timezone for timestamps that don’t include an offset, such as
04/06/2016 12:41:45.
Use a Unix TZ value, such as America/New_York, Local to use the system
timezone, or UTC.
Type: string
Default: "" (UTC)