Documentation

Manage your data using InfluxQL

Use the following data management commands to write and delete data with InfluxQL:

Write data with INSERT

The INSERT statement writes line protocol to a database and retention policy.

Syntax

INSERT [INTO <database>[.<retention-policy>]] <line-protocol>
  • The INTO clause is optional. If the command does not include INTO, you must specify the database with USE <database_name> when using the InfluxQL shell or with the db query string parameter in the InfluxDB 1.x compatibility API request.

Examples

Insert data into the a specific database and retention policy

INSERT INTO mydb.myrp example-m,tag1=value1 field1=1i 1640995200000000000

Insert data into the a the default retention policy of a database

INSERT INTO mydb example-m,tag1=value1 field1=1i 1640995200000000000

Insert data into the currently used database

The following example uses the InfluxQL shell.

> USE mydb
> INSERT example-m,tag1=value1 field1=1i 1640995200000000000

Delete series with DELETE

The DELETE statement deletes all points from a series in a database.

Syntax

DELETE FROM <measurement_name> WHERE [<tag_key>='<tag_value>'] | [<time interval>]

You must include either the FROM clause, the WHERE clause, or both.

  • DELETE supports regular expressions in the FROM clause when specifying measurement names and in the WHERE clause when specifying tag values.
  • DELETE does not support fields in the WHERE clause.

Examples

Delete all measurement data

Delete all data associated with the measurement h2o_feet:

DELETE FROM "h2o_feet"

Delete data in a measurement that has a specific tag value

Delete all data associated with the measurement h2o_quality and where the tag randtag equals 3:

DELETE FROM "h2o_quality" WHERE "randtag" = '3'

Delete data before or after specified time

Delete all data in the database that occur before January 01, 2020:

DELETE WHERE time < '2020-01-01'

A successful DELETE query returns an empty result.

If you need to delete points in the future, you must specify the future time period because DELETE SERIES runs for time < now() by default.

Delete future points:

DELETE FROM device_data WHERE "device" = 'sensor1" and time > now() and < '2024-01-14T01:00:00Z'

Delete points in the future within a specified time range:

DELETE FROM device_data WHERE "device" = 'sensor15" and time >= '2024-01-01T12:00:00Z' and <= '2025-06-30T11:59:00Z'

Delete measurements with DROP MEASUREMENT

The DROP MEASUREMENT statement deletes all data and series from the specified measurement and deletes the measurement from the index.

Syntax

DROP MEASUREMENT <measurement_name>

Example

Delete the measurement h2o_feet:

DROP MEASUREMENT "h2o_feet"

A successful DROP MEASUREMENT query returns an empty result.

The DROP MEASUREMENT command is very resource intensive. We do not recommend this command for bulk data deletion. Use the DELETE FROM command instead, which is less resource intensive.


Was this page helpful?

Thank you for your feedback!


The future of Flux

Flux is going into maintenance mode. You can continue using it as you currently are without any changes to your code.

Flux is going into maintenance mode and will not be supported in InfluxDB 3.0. This was a decision based on the broad demand for SQL and the continued growth and adoption of InfluxQL. We are continuing to support Flux for users in 1.x and 2.x so you can continue using it with no changes to your code. If you are interested in transitioning to InfluxDB 3.0 and want to future-proof your code, we suggest using InfluxQL.

For information about the future of Flux, see the following:

InfluxDB Cloud powered by TSM